Amico Induk

0
  • on Rabu, 11 Juli 2012
  • AMICO ROTARY-WING WATER METER
    HORIZONTALWOLTMAN TYPE WATER METER







    TYPE LXSG 50E
    Dry Dial Water Meter











    TYPE LXLC 80 - 300 G2
    Dry Dial Water Meter




















    Special Features :
    • Digital-Wheel counter mechanism for direct reading
    • Large range for measuring, good accuracyin flowrate
    • High continuous flow capacity, lower head loss
    • Steady curve characteristics
    • Performance of type LXLC water meteris up to standard ISO 4064 B


    Meter Design :
    • Solid and robust design, long service guaranteed
    • Selected high quality materials guarantee
    • Universal interchangeable measuring insert



    Metrological Data :

    Meter Size
    DN
    mm

    Measuring
    Class

    Nominal
    Flowrate
    Qn

    m3/h

    Minimum
    Flowrate
    Qmin

    Transitional
    flowrate
    Qt

    Min.
    reading

    Max.
    reading

    m3/h

    m3

    50

    A

    30

    1,2

    4,5

    0.01

    999999.99

    B

    0,45

    3

    80

    A

    40

    3.2

    12

    B

    1.2

    8

    100

    A

    60

    4.8

    18

    B

    1.8

    12

    150

    A

    150

    12

    45

    B

    4.5

    30

    200

    A

    250

    20

    75

    0.1

    999999.99

    B

    7.5

    50

    250

    A

    400

    120

    32

    B

    80

    12

    300

    A

    600

    180

    48

    0,1

    999999

    B

    120

    18

    400

    A

    1000

    300

    80

    B

    200

    30

    Working Condition :

    Water Temperature : For Cold Water 50oC

    Water Pressure : 1 MPa


    Dimensions and Weights :

    DN
    mm

    Length
    (L)
    mm

    Height
    (H)
    mm

    connecting flange

    Weight
    kg

    outer dia,
    D

    bolt circle dia,
    D 1

    Conneting bolt
    x pcs

    50

    230

    190

    165

    125

    M16 x4

    12.8

    80

    225

    269

    200

    160

    M16 X8

    15.4

    100

    250

    279

    220

    180

    M16 x 8

    17.6

    150

    300

    309

    285

    240

    M20 X 8

    28

    200

    350

    375

    340

    295

    M20 x 8

    38.5


    Features curve diagram :

    Reading errror : The Max. reading error between Qmax (max. flowrate ) and Qt (Transitional flowrate) for cold water meter is ± 2% The Max. reading error between Qe (Transitional flowrate) and Qmin (minimum flowrate) not including Qt. is ± 5%

    Flow Error Curve :





    Pressure Loss Curve :